Please note, our sales office will be closed from Dec 23rd until Jan 2nd. Happy Holidays!


Thermboard HP+ Thermal Laminate 2.4m x 1.2m - All Sizes
This product is a call to enquire product. Please call us on 020-3582-6399 for more information.
The option you have currently selected is a call to enquire option. Please call us on 020-3582-6399 for more information or select an alternative option.
Regular price
£645.12 £774.14
Was:
£0.00
Now Only:
£645.12 £774.14
Sold out
Unit price
per 

How much will I need?

Coverage required
x

We recommend adding 10% of additional product to the calculation to account for errors, damages, and obstacles in your project

Based on your total area of 0m2 (inc. 10% wastage) you will need 1 of this product (total coverage ).
Calculate
+
Add SampleAdd Sample
THERMBOARD

Thermboard HP+ Thermal Laminate 2.4m x 1.2m - All Sizes (Price Per Pallet)

SKU: THERMHP25.5

Est Delivery between and .

A 12.5mm TE plasterboard bonded to HP+ EPS E grade grey polystyrene (Thermal Conductivity 0.030 W/mk). Thermboard HP+ is for the thermal insulation of internal walls and roofs. The board size is 2400mm x 1200 mm (nominal).

Installation & Application

The following notes are for general guidance only; and your consideration should be given to the design requirements of the local and National Building Regulations to achieve the required thermal performance at the time of installation.

Installation Guide

The substrate for installation should be dry, free from debris, and be of suitable load bearing capability for the weight of the board(s) to be installed. Any framework or batten system being used for installation should be installed at a maximum of 600mm centres. The board edges need to overlap any framework by a minimum of 20mm to ensure adequate support. Boards on walls should be installed with the long edges vertically with the joints between boards neatly butted to allow for either joint or skim finishing.

Any cables or services must be installed within some form of conduit to ensure that they do not come into direct contact with the insulation, and the insulation should not be notched out to accommodate any of these services within the insulation, as this could be detrimental to the thermal performance.

Mechanical fixings should always be used to secure the boards in addition to any adhesive method that has been employed. These fixings should provide a minimum of 25mm embedment into the substrate and must be driven below the surface of the board to allow joint or skim finishing. Fixings should be a minimum of 10mm from any edge.

There should be a 5-10mm tolerance between the junction of both the ceiling & floor joints, which should be filled with a suitable flexible sealant prior to final finishes.

Boards can be cut using a Plasterboard Saw or sharp Utility Knife or power tool if being employed by a competent person. Holes for sockets etc. should be cut out prior to the installation of the board to the wall or roof that is being dry lined.

Where there is a requirement for the fixing of heavy items; these must be secured directly onto a framework that is installed behind the laminate board securely fixed to the substrate to ensure adequate support.

When the boards are to be secured to the underside of a roof, they should be installed horizontal at 90 degrees to the rafters, with noggins installed as necessary to support the ends of the boards.

Any decoration should be undertaken after the jointing or skim finishing has been undertaken in a timely fashion.

Brand Thermboard

Est Delivery between and .

Delivery will always take place on a weekday (Mon - Fri).
For more information on delivery visit our delivery info page.

We use cookies to improve your user experience. View Privacy Policy
Accept