Collection: Pipe Insulation
Protect your pipes against frost and prevent heat loss. Browse our range of pipe insulation below.
Pipe insulation is a thermal layer fitted around hot or cold pipework to reduce heat transfer, limit condensation and slow heat loss in freezing conditions. For domestic heating and hot-water services, BS 5422:2023 sets insulation thickness by pipe outside diameter and the insulation’s thermal conductivity rather than using one thickness for every pipe.
|
Range |
Material |
Live pipe diameters |
Live insulation thicknesses / length |
Verified thermal data |
|
Climaflex |
Closed-cell polyethylene |
15–76mm |
9, 13, 19, 25mm; 1m/2m options |
0.036 W/mK at 0°C; 0.040 W/mK at 40°C (NMC UK TDS) |
|
Tubolit |
Closed-cell polyethylene |
15–76mm |
9, 13, 19, 25mm; 1m/2m options |
0.040 W/mK at 40°C for current Tubolit DG (Armacell) |
|
Armaflex Evo |
Closed-cell elastomeric foam |
6–108mm |
6, 9, 13, 19, 25, 32mm; 2m |
0.033 W/mK at 0°C and 0.038 W/mK at 40°C for AF-EVO-1 to -4 tubes (Armacell) |
|
Rubaflex self-seal |
Closed-cell elastomeric foam |
15–114mm |
9, 13, 19, 25, 32, 40mm; 2m |
0.033 W/mK at 0°C and 0.037 W/mK at 40°C at ≤25mm (Davant guide) |
Use the product filters to match the pipe diameter, insulation thickness and format to the job, or call 020 3582 6399 for help with quantities and specification.
Collection: Pipe Insulation
Protect your pipes against frost and prevent heat loss. Browse our range of pipe insulation below.
Pipe insulation is a thermal layer fitted around hot or cold pipework to reduce heat transfer, limit condensation and slow heat loss in freezing conditions. For domestic heating and hot-water services, BS 5422:2023 sets insulation thickness by pipe outside diameter and the insulation’s thermal conductivity rather than using one thickness for every pipe.
|
Range |
Material |
Live pipe diameters |
Live insulation thicknesses / length |
Verified thermal data |
|
Climaflex |
Closed-cell polyethylene |
15–76mm |
9, 13, 19, 25mm; 1m/2m options |
0.036 W/mK at 0°C; 0.040 W/mK at 40°C (NMC UK TDS) |
|
Tubolit |
Closed-cell polyethylene |
15–76mm |
9, 13, 19, 25mm; 1m/2m options |
0.040 W/mK at 40°C for current Tubolit DG (Armacell) |
|
Armaflex Evo |
Closed-cell elastomeric foam |
6–108mm |
6, 9, 13, 19, 25, 32mm; 2m |
0.033 W/mK at 0°C and 0.038 W/mK at 40°C for AF-EVO-1 to -4 tubes (Armacell) |
|
Rubaflex self-seal |
Closed-cell elastomeric foam |
15–114mm |
9, 13, 19, 25, 32, 40mm; 2m |
0.033 W/mK at 0°C and 0.037 W/mK at 40°C at ≤25mm (Davant guide) |
Use the product filters to match the pipe diameter, insulation thickness and format to the job, or call 020 3582 6399 for help with quantities and specification.
-
Climaflex Pipe Insulation - All Sizes
Vendor:ClimaflexfromClimaflexFree Delivery over £350£420Regular price £66.55 £79.86Sale price £66.55 £79.86 Regular priceUnit price per£0.00 -
Rubaflex Class O Nitrile Pipe Insulation SLIT - All Sizes
Vendor:RubaflexfromRubaflexFree Delivery over £350£420Regular price £102.73 £123.28Sale price £102.73 £123.28 Regular priceUnit price per£0.00 -
Armaflex Evo Pipe Insulation SLIT - All Sizes
Vendor:ArmaflexfromArmaflexFree Delivery over £350£420Regular price £183.58 £220.30Sale price £183.58 £220.30 Regular priceUnit price per£0.00 -
Tubolit Polyethylene Pipe Insulation - All Sizes
Vendor:TubolitfromTubolitFree Delivery over £350£420Regular price £85.33 £102.40Sale price £85.33 £102.40 Regular priceUnit price per£0.00 -
Armaflex Evo Pipe Insulation UN-SLIT - All Sizes
Vendor:ArmaflexfromArmaflexFree Delivery over £350£420Regular price £163.88 £196.66Sale price £163.88 £196.66 Regular priceUnit price per£0.00 -
Rubaflex Class O Nitrile Pipe Insulation UN-SLIT - All Sizes
Vendor:RubaflexfromRubaflexFree Delivery over £350£420Regular price £102.73 £123.28Sale price £102.73 £123.28 Regular priceUnit price per£0.00 -
Pipe Inuslation Tape 3mm x 50mm x 15m
Vendor:RubaflexRubaflexFree Delivery over £350£420Regular price £38.75 £46.50Sale price £38.75 £46.50 Regular priceUnit price per£0.00 -
Class O Nitrile Self Seal Pipe Insulation - All Sizes
Vendor:RubaflexfromRubaflexFree Delivery over £350£420Regular price £127.99 £153.59Sale price £127.99 £153.59 Regular priceUnit price per£0.00 -
High Temperature Pipe Insulation Adhesive - All Sizes
Vendor:ArmaflexfromArmaflexFree Delivery over £350£420Regular price £23.64 £28.37Sale price £23.64 £28.37 Regular priceUnit price per£0.00 -
Class O Pipe Insulation Tape 50mm x 15m x 3mm Black
Vendor:ArmaflexArmaflexFree Delivery over £350£420Regular price £31.26 £37.51Sale price £31.26 £37.51 Regular priceUnit price per£0.00 -
High Temperature Pipe Insulation UN-SLIT - All Sizes
Vendor:ArmaflexfromArmaflexFree Delivery over £350£420Regular price £229.13 £274.96Sale price £229.13 £274.96 Regular priceUnit price per£0.00 -
Polyethylene Pipe Insulation Sealing Clips (50 Clips per Bag)
Vendor:DavantDavantFree Delivery over £350£420Regular price £6.66 £7.99Sale price £6.66 £7.99 Regular priceUnit price per£0.00 -
Pipe Insulation Adhesive - All Sizes
Vendor:ArmaflexfromArmaflexFree Delivery over £350£420Regular price £13.85 £16.62Sale price £13.85 £16.62 Regular priceUnit price per£0.00 -
Pipe Insulation Lagging Tape 3mm x 50mm x 15m
Vendor:ArmaflexArmaflexFree Delivery over £350£420Regular price £79.22 £95.06Sale price £79.22 £95.06 Regular priceUnit price per£0.00 -
PE Tape 3mm x 50mm x 10m Grey
Vendor:DavantDavantFree Delivery over £350£420Regular price £39.76 £47.71Sale price £39.76 £47.71 Regular priceUnit price per£0.00 -
28mm Pipe Lagging - All Lengths
Vendor:CelafeltfromStandardFree Delivery over £350£420Regular price £143.53 £172.24Sale price £143.53 £172.24 Regular priceUnit price per£0.00 -
15-22mm Pipe Lagging - All Lengths
Vendor:CelafeltfromStandardFree Delivery over £350£420Regular price £207.06 £248.47Sale price £207.06 £248.47 Regular priceUnit price per£0.00
Insulation4less offers a vast range of high-quality pipe insulation products, catering to various needs. Pipe insulation is essential for maintaining temperature within pipes, conserving energy, and providing freeze protection. Whether you are a professional contractor or a DIY enthusiast, understanding the different types of products in this category can help in selecting the right insulation solution.
How to choose pipe insulation
The right pipe insulation starts with the service, not the colour of the foam. A hot central-heating pipe mainly needs heat-loss control. A cold-water or chilled line also needs condensation control. Pipework in a loft, garage or other cold space needs enough insulation to slow cooling, but insulation does not generate heat and cannot guarantee that standing water will never freeze during a prolonged cold spell. For exposed or genuinely freeze-critical services, the complete protection strategy may also need weather protection, suitable trace heating or a change in pipe routing.
Measure the pipe outside diameter before ordering. The bore of the insulation should fit the pipe without being stretched open or leaving a gap. Then choose the wall thickness. BS 5422:2023 uses both pipe diameter and declared thermal conductivity when setting thicknesses for domestic heating and hot-water services. This is why a 9mm sleeve and a 25mm sleeve are not interchangeable simply because both fit a 22mm pipe.
| Job | Best starting point | Why |
|---|---|---|
| Domestic heating / hot-water pipework | Polyethylene such as Climaflex or Tubolit, sized to the service requirement | Straightforward thermal insulation for heating and plumbing; light and easy to cut. |
| Cold or chilled pipework where condensation control matters | Closed-cell elastomeric foam such as Armaflex Evo or Rubaflex | Flexible closed-cell construction is designed for mechanical services and vapour-control duties. |
| Fast retrofit over accessible straight pipe | Slit or self-seal tube | The longitudinal opening allows fitting without disconnecting the pipe. |
| New work before pipe connections are completed | Unslit tube | Can be slid over the pipe and keeps the longitudinal wall continuous. |
| Higher-temperature service | Use the dedicated high-temperature Armaflex product and its current datasheet | Do not assume standard PE or nitrile products share the same service-temperature limit. |
Standard Pipe Insulation
These are primarily used for thermal insulation of domestic and commercial pipes.
Climaflex Pipe Insulation: Manufactured by Climaflex, this insulation is versatile and comes in all sizes. Suitable for general insulation needs.
Tubolit Polyethylene Pipe Insulation: Offered by Tubolit, it’s a cost-effective solution made from polyethylene and is available in all sizes.
28mm & 15-22mm Pipe Lagging by Celafelt: These lagging solutions from Celafelt come in specific diameters and lengths, perfect for various pipe sizes.
Nitrile Based Pipe Insulation
These are made from synthetic rubber and are flexible, making them ideal for tight spaces and corners.
Armaflex Class O Nitrile Pipe Insulation: Both slit and un-slit versions are available. Manufactured by Armaflex, they provide excellent thermal properties.
Rubaflex Class O Nitrile Pipe Insulation: With options in both slit and un-slit, Rubaflex ensures durability and thermal efficiency.
Class O Nitrile Self Seal Pipe Insulation by Rubaflex: This offers a self-seal feature, making installation easier and more efficient.
Pipe Insulation Accessories
Essential components for a complete insulation job.
High Temperature Pipe Insulation Adhesive by Armaflex: For situations where high temperature resistance is required.
Pipe Insulation Adhesive by Armaflex: Standard adhesive for affixing insulation.
Class O Pipe Insulation Tape & Pipe Insulation Lagging Tape by Armaflex: Perfect for sealing joins and ensuring no heat loss.
Pipe Insulation Tape & PE Tape by Rubaflex and Davant: Essential for sealing and enhancing insulation integrity.
Polyethylene Pipe Insulation Sealing Clips by Davant: Helps in keeping the insulation in place.
What thickness of pipe insulation should I use?
There is no single correct wall thickness for every pipe. For domestic heating and hot-water systems, BS 5422:2023 Table 20A gives base-level thicknesses according to the pipe outside diameter and the insulation conductivity at 40°C. For an insulation material at 0.035 W/mK, the table specifies 15mm on pipe up to 15mm outside diameter, 18mm on pipe up to 22mm and 20mm on pipe up to 28mm. These are service-design figures, not a claim that every sleeve sold in that nominal thickness automatically complies in every installation.
Does pipe insulation stop pipes freezing?
Pipe insulation reduces the rate at which a pipe loses heat, so it can delay freezing and reduce risk, but it cannot make a water-filled pipe permanently freeze-proof. If the surrounding temperature remains below freezing for long enough and no heat enters the pipe, the water can still cool to freezing point. That distinction matters in lofts, garages, outbuildings and external runs. A thicker, correctly fitted sleeve gives more resistance to heat flow, but gaps at joints, fittings and ends create weak points.
For a vulnerable external or unheated run, first remove avoidable exposure: seal draught paths where appropriate, keep insulation continuous and protect insulation from weather and physical damage. Where the design requires reliable freeze protection, use a properly specified system rather than treating foam lagging as a heat source. Any trace-heating system must be selected and installed for the pipe, insulation and environment in question.
Fitting pipe insulation without leaving thermal gaps
Dry, clean pipework is easier to insulate properly. Cut sleeves square with a sharp knife and keep butt joints tight. At bends and tees, shape the insulation so the pipe is covered continuously rather than leaving bare copper or plastic at the fitting. On cold services, continuity of the vapour-control layer is especially important because warm, moisture-laden air reaching a cold pipe can condense at gaps.
Do not crush thick insulation into a space that is too small. Compression changes the installed geometry and can leave open seams. Where pipe clips or supports interrupt the insulation, detail them to the system specification. For external pipework, the insulation also needs a suitable weather-resistant finish or product system; ordinary indoor foam should not be assumed to be a finished UV- and weatherproof jacket.
Pipe insulation FAQs
What is the best insulation for pipes?
Closed-cell polyethylene is a practical choice for ordinary domestic heating and plumbing, while closed-cell elastomeric foam is generally the better starting point for chilled water, refrigeration and condensation-sensitive services. The correct choice still depends on operating temperature, pipe diameter, required thickness, fire classification and whether the run is indoors or exposed.
Does pipe insulation stop pipes freezing?
Pipe insulation slows heat loss and can delay freezing, but it does not generate heat. Water can still freeze if the surrounding temperature remains low for long enough. In vulnerable locations, fit the correct thickness continuously and consider the wider freeze-protection design, including draught control, pipe routing or correctly specified trace heating.
What size insulation do I need for a 15mm pipe?
Choose insulation with a bore intended for a 15mm outside-diameter pipe, then select the wall thickness separately. The live Insulation4Less ranges include several thickness choices for 15mm pipe. Do not confuse the 15mm pipe bore size with the insulation wall thickness; they describe two different dimensions.
What size insulation do I need for a 22mm pipe?
Choose a 22mm bore for standard 22mm outside-diameter pipework, then select the insulation wall thickness for the service. Insulation4Less lists 22mm options across polyethylene and nitrile ranges. For domestic heating and hot water, BS 5422 thickness depends on the material’s thermal conductivity as well as pipe diameter.
Is 9mm pipe insulation thick enough?
A 9mm wall can be useful where space is restricted or where the product specification permits it, but it is not a universal domestic-heating thickness. BS 5422:2023 Table 20A requires thicker insulation for many common pipe diameters at typical conductivity values. Check the service, pipe size and declared λ-value before ordering.
What is the difference between pipe lagging and pipe insulation?
In everyday UK trade use, pipe lagging and pipe insulation usually describe the same basic job: insulating pipework to reduce heat transfer. The important distinction is the material and specification. Polyethylene foam, elastomeric nitrile foam and specialist high-temperature products have different thermal, fire, moisture and service-temperature properties.
Can I use pipe insulation on cold-water pipes?
Yes. Closed-cell pipe insulation can reduce heat gain and help control surface condensation on cold water services when correctly specified and installed. Condensation control depends on insulation thickness and vapour-seal continuity. Seal joints and fittings carefully, because gaps can allow humid air to reach the colder pipe surface.
Can pipe insulation be used outside?
Only where the product and finish are suitable for external exposure. Outdoor insulation can face rain, UV, wind and physical damage, so an indoor foam sleeve should not automatically be treated as a finished weatherproof system. Check the manufacturer’s external-use requirements and provide the specified protective jacket or coating where required.
Is nitrile pipe insulation better than polyethylene?
Neither material is best for every job. Polyethylene is a straightforward option for many heating and plumbing runs. Flexible elastomeric nitrile foam is commonly specified where condensation control, chilled water, refrigeration or HVAC duties are important. Compare declared conductivity, temperature range, fire classification, vapour performance and installation format.
What is self-seal pipe insulation?
Self-seal insulation is pre-slit tube insulation with factory-applied adhesive along the longitudinal opening. It is designed to speed installation around existing pipework. The pipe and bonding surfaces must be clean and the seam closed according to the manufacturer’s instructions. Joints, bends and fittings still need correct system detailing.
How do I measure for pipe insulation?
Measure the pipe’s outside diameter, not its circumference and not the fitting size printed on unrelated components. Match that diameter to the insulation bore, then choose the required wall thickness and length. For existing copper pipework, confirm the actual outside diameter before ordering rather than relying only on a visual estimate.