Celotex Board Thickness Guide: How to Choose the Right Insulation Depth

Celotex Board Thickness Guide: How to Choose the Right Insulation Depth

Why Board Thickness Matters

Celotex PIR (polyisocyanurate) insulation boards deliver high thermal performance in a slim profile — but choosing the wrong thickness can mean a failed Building Regulations inspection or wasted spend. This guide helps you match the right board depth to your project type and U-value target.

Understanding U-Values

A U-value measures how quickly heat passes through a building element (walls, roofs, floors). The lower the U-value, the better the insulation. UK Building Regulations set maximum U-values for new builds and extensions:

  • Pitched roofs (between rafters): 0.18 W/m²K
  • Flat roofs: 0.18 W/m²K
  • External walls: 0.30 W/m²K (0.18 for new builds)
  • Ground floors: 0.25 W/m²K (0.15 for new builds)

Celotex PIR has a thermal conductivity (lambda value) of typically 0.022–0.023 W/mK, one of the best available for rigid board insulation.

Celotex Thickness by Application

Pitched Roof — Between Rafters (Cold Loft / Warm Roof)

For a warm roof with 150mm rafters, a 100mm Celotex GA4000 board between the rafters combined with a 40mm board below (counter-batten layer) is a common approach to achieve 0.18 W/m²K. Thicker rafters allow full-fill solutions with a single layer of 150mm board.

  • Shallow rafters (100mm): Use 70mm + 25mm counter-batten layer
  • Deep rafters (175mm+): Single 150mm board may suffice

Flat Roof (Above Deck)

Flat roofs typically require 120mm–150mm of PIR above the deck to hit 0.18 W/m²K, depending on the deck construction. Celotex FR5000 and GA4000 are both suitable for above-deck applications.

Solid or Suspended Timber Floors

For ground floors, 70mm–100mm of Celotex GA4000 between joists, or a continuous layer of 50mm–75mm below a screed, is typically required to achieve 0.25–0.15 W/m²K targets depending on floor dimensions.

Internal Wall Insulation (Dot-and-Dab)

Slim-profile applications on solid walls typically use 37.5mm or 52.5mm Celotex PL4000 plasterboard-faced boards. These are factory-laminated with 12.5mm plasterboard for a finished wall ready for decoration.

Quick Thickness Reference Table

Application Target U-Value Typical Celotex Thickness Product
Pitched roof (between rafters) 0.18 W/m²K 100mm + 40mm GA4000
Flat roof (above deck) 0.18 W/m²K 120mm–150mm GA4000 / FR5000
Ground floor (between joists) 0.25 W/m²K 70mm–100mm GA4000
Solid wall (internal) 0.30 W/m²K 37.5mm–52.5mm PL4000
Timber frame wall (cavity) 0.18 W/m²K 90mm–140mm GA4000

How to Calculate the Thickness You Need

Use this simplified formula as a starting point:

Required thickness (m) = Lambda value ÷ Target U-value

For Celotex GA4000 (lambda = 0.022 W/mK) targeting 0.18 W/m²K in isolation:

0.022 ÷ 0.18 = 0.122m (122mm)

In practice, existing construction layers contribute to the overall U-value, so you may need less. Always use a full U-value calculator or consult Celotex's technical support for a precise specification.

Common Mistakes to Avoid

  • Mixing lambda values: Not all PIR boards have identical lambda values. Always check the product datasheet — GA4000 is 0.022 W/mK, while some boards are 0.023 W/mK.
  • Ignoring thermal bridging: Rafters, joists, and studs create cold bridges that reduce the effective U-value. Account for these in your calculation.
  • Under-ordering: Always add 5–10% for cutting waste, especially on roofs with hips, valleys, or rooflights.
  • Skipping vapour control: PIR boards are vapour-resistant but not vapour-proof. Confirm whether a separate VCL is required for your build-up.